Sensor
Displacement Measurement Sensors SICK OD Value
Type:OD2-N30W04U2
Part No.:6036569
Part No.:6036569
Displacement Measurement Sensors SICK OD Value OD2-N30W04U2
Mechanics/electronics
Performance
Interfaces
Ambient data
Classifications
Mechanics/electronics
| Supply voltage Vs | DC 18 V ... 24 V |
| Power consumption | ≤ 2.88 W 1) |
| Warm-up time | ≤ 30 min |
| Housing material | Plastic (PBT) |
| Window material | Plastic (PMMA) |
| Connection type | Cable, 2 m |
| Indication | Distance bar graph, up to 8 status LEDs |
| Weight | 70 g |
| Dimensions (W x H x D) | 20.4 mm x 60 mm x 50 mm |
| Enclosure rating | IP67 |
| Protection class | III |
- 1) Without load, with current output.
Performance
| Measuring range | 26 mm ... 34 mm 1) |
| Target | Natural objects |
| Repeatability | 2 µm 2) 3) 4) |
| Linearity | ± 8 µm 2) 3) 5) |
| Response time | ≥ 1 ms |
| Measuring frequency | ≤ 2 kHz 1) |
| Output time | ≥ 0.5 ms |
| Light source | Laser, red visible red light |
| Laser class | 2 (IEC 60825-1:2014, EN 60825-1:2014) 6) |
| Typ. light spot size (distance) | 0.1 mm x 0.1 mm (30 mm) |
| Additional function | Mean-value setting 1 … 64x, automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of digital output, Invertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO), switching mode: window (Wnd) |
- 1) 6 % ... 90 % remission.
- 2) Measurement on 90 % remission (ceramic, white).
- 3) At averaging function medium.
- 4) Constant ambient conditions.
- 5) When calibrated in the application regularly.
- 6) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
|
|||||||||||
|
|||||||||||
| Multifunctional input (MF) | 1 x MF 2) | ||||||||||
- 1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
- 2) MF can be used as laser-off, trigger, external teach-in, or deactivated; response time ≤ 3 ms.
Ambient data
| Ambient temperature, operation | –10 °C ... +40 °C |
| Ambient temperature, storage | –20 °C ... +60 °C |
| Relative air humidity (non-condensing) | 35 % ... 95 % |
| Temperature drift | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
| Typ. Ambient light immunity |
Artificial light: ≤ 3,000 lx Sunlight: ≤ 10,000 lx |
| Vibration resistance | 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
| Shock resistance | 50 G (x, y, z axis 3 times each) |
Classifications
| ECl@ss 5.0 | 27270801 |
| ECl@ss 5.1.4 | 27270801 |
| ECl@ss 6.0 | 27270801 |
| ECl@ss 6.2 | 27270801 |
| ECl@ss 7.0 | 27270801 |
| ECl@ss 8.0 | 27270801 |
| ECl@ss 8.1 | 27270801 |
| ECl@ss 9.0 | 27270801 |
| ECl@ss 10.0 | 27270801 |
| ECl@ss 11.0 | 27270801 |
| ETIM 5.0 | EC001825 |
| ETIM 6.0 | EC001825 |
| ETIM 7.0 | EC001825 |
| ETIM 8.0 | EC001825 |
| UNSPSC 16.0901 | 41111613 |