Product Price Quantity Delete

    Motor, PLC&HMI

    Omron PLC CP-series CP1E CPU Units CP1E-E14SDR-A CP1E-E20SDR-A/E30SDR-A

    Omron PLC


     
    Type AC power supply models DC power supply models
    Model CP1E-@@@S@D@-A CP1E-@@@D@-A CP1E-@@@S@D@-D CP1E-@@@D@-D
    Enclosure Mounted in a panel
     

     

     

     

     

    Dimensions (H × D × W)

    E/N/NA@@-type

     

    CPU Unit with 10 I/O points (CP1E-E10D@@): 90mm *1 × 85mm *2 × 66 mm

    CPU Unit with 14 or 20 I/O points (CP1E-@14D@@/@20D@@): 90mm *1 × 85mm *2 × 86 mm CPU Unit with 30 I/O points (CP1E-@30D@@): 90mm *1 × 85mm *2 × 130 mm

    CPU Unit with 40 I/O points (CP1E-@40D@@): 90mm *1 × 85mm *2 × 150 mm CPU Unit with 60 I/O points (CP1E-N60D@@): 90mm *1 × 85mm *2 × 195 mm

    CPU Unit with 20 I/O points and built-in analog (CP1E-NA20D@@): 90mm *1 × 85mm *2 × 130 mm

    E/N/@@S(1)-type

    CPU Unit with 14 or 20 I/O points (CP1E-@14SD@@/@20SD@@): 90mm *1 × 79mm *2 × 86 mm CPU Unit with 30 I/O points (CP1E-@30S(1)D@@): 90mm *1 × 79mm *2 × 130 mm

    CPU Unit with 40 I/O points (CP1E-@40S(1)D@@): 90mm *1 × 79mm *2 × 150 mm CPU Unit with 60 I/O points (CP1E-@60S(1)D@@): 90mm *1 × 79mm *2 × 195 mm

     

     

     

     

    Weight

    CPU Unit with 10 I/O points (CP1E-E10D@@): 300g max. CPU Unit with 14 I/O points (CP1E-@14(S)D@@): 360g max. CPU Unit with 20 I/O points (CP1E-@20(S)D@@): 370g max.

     

    CPU Unit with 30 I/O points (CP1E-@30(S@)D@@): 600g max. CPU Unit with 40 I/O points (CP1E-@40(S@)D@@): 660g max. CPU Unit with 60 I/O points (CP1E-@60(S@)D@@): 850g max.

    CPU Unit with 20 I/O points and built-in analog (CP1E-NA20D@@): 680g max.

    Supply voltage 100 to 240 VAC 50/60 Hz 24 VDC
    Operating voltage range 85 to 264 VAC 20.4 to 26.4 VDC
     

     

     

     

    Power consumption

    15 VA/100 VAC max.

     

    25 VA/240 VAC max.

    (CP1E-E10D@-A/@14(S)D@-A/@20(S)D@-A)

    9 W max. (CP1E-E10D@-D)

     

    13 W max. (CP1E-N14D@-D/N20D@-D)

      50 VA/100 VAC max.

     

    70 VA/240 VAC max.

    (CP1E-NA20D@-A/@30(S@)D@-A/@40(S@)D@-A/ N60(S@)D@-A)

    20 W max.

     

    (CP1E-NA20D@-D/N30(S@)D@-D/N40(S@)D@-D/ N60(S@)D@-D) *4

     

     

    Inrush current

    120 VAC, 20 A for 8 ms max. for cold start at room temperature

     

    240 VAC, 40 A for 8 ms max. for cold start at room temperature

     

     

    24 VDC, 30 A for 20 ms max. for cold start at room temperature

     

     

    External power supply

    *3

    Not provided.

     

    (CP1E-E10D@-A/@14(S)D@-A/@20(S)D@-A) 24 VDC, 300 mA

    (CP1E-NA20D@-A/@30D@-A/@40D@-A/@60D@-A/

    @30SDR-A/@40SDR-A/@60SDR-A)

     

     

     

    Not provided

    Insulation resistance 20 MΩ min. (at 500 VDC) between the external AC terminals and GR terminals Except between DC primary current and DC secondary current
    Dielectric strength 2,300 VAC 50/60Hz for 1 min between AC external and GR terminals Leakage current: 5 mA max. Except between DC primary current and DC secondary current
    Ambient operating temperature 0 to 55 °C
    Ambient humidity 10% to 90%
    Atmosphere No corrosive gas.
    Ambient storage temperature -20 to 75 °C (excluding battery)
    Altitude 2,000 m max.
    Pollution degree 2 or less: Meets IEC 61010-2-201.
    Noise resistance 2 kV on power supply line (Conforms to IEC61000-4-4.)
    Overvoltage category Category II: Meets IEC 61010-2-201.
    EMC Immunity Level Zone B
    Vibration resistance Conforms to JIS 60068-2-6.

     

    5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz

    Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)

    Shock resistance Conforms to JIS 60068-2-27.

     

    147 m/s2, 3 times in X, Y, and Z directions

    Terminal block Fixed (not removable)
    Terminal screw size M3
    Applicable standards Conforms to EC Directive
    Grounding method Ground to 100 Ω or less.